Explain what do you mean by "vcenter does not work" ? If you keep it more detailed we can provide better answers to this.
With new VC; you will loose vDS and RP's (If old VC DB cannot be used)
Explain what do you mean by "vcenter does not work" ? If you keep it more detailed we can provide better answers to this.
With new VC; you will loose vDS and RP's (If old VC DB cannot be used)
Hi MITTECH20
Power on the master image > Check if any windows update is pending > Apply all windows updates > Make sure DNS server is correctly set and gold image is not joined to domain.
Take a new snapshot and check if you are able to create new pool.
Looks like windows store app is stuck at updating even though you have disabled it. Can you completely remove MS store from image and try again?
Get-AppxPackage Microsoft.WindowsStore | Remove-AppxPackage
If the issue still persist,
Hi Mickeybyte
We are also testing FSLogix and I would like to know your backup strategy for the VHDs. Since the VHDs will be attached to the VM, what could be the best backup strategy?
Hi jgkurz
What do you mean by vApp here because its a container for your VMs in vSphere? Are you referring to published application Or you mean you are unable to connect to VDIs which are present under that vApp?
esxi up to ver 6.0 will run on this board (GA-Z77-DS3M), with the atl1 driver added, fails in uefi mode to detect the ethernet. (probe failed)
ESXi does not support Chipset/Fakeraids.
Regards,
Joerg
We've fully resolved the issue by upgrading to VMware Tools v11.1.0.
VMware Tools 11.1.0 Release Notes
You'll need to set up a VMware Tools repository to deploy it as 11.1.0 isn't shipping with ESXi releases yet.
https://blogs.vmware.com/vsphere/2019/01/configure-a-vmware-tools-repo-in-vsphere-6-7u1.html
This repository is only available in vSphere 6.7u1+, so you'll need to use Update Manager or some other means to deploy the updated tools in earlier versions.
I have confirmed this is a known issue with the GDM3 greeter ui. The workaround is to have a window size at or smaller that 800x600, then the screen refreshes as expected. Any higher than that it doesn't work. VMWare say this is an Gnome issue not a VMWare agent issue.
I'm new to workstation and I wish to enable the above listed features. I went through the documents of VMware in which they said the options are under the Guest Isolation Option. There is no Guest Isolation option in my case. I've searched thoroughly. I was using workstation 12 before and have upgraded to workstation 15 to see if it makes some differences.
In the documents for Copy n Paste feature, they said VMware Tools must be installed. I am beginning to think if that is the reason. So I went to download VMware Tools. Now I'm confused.
There is a Disclosure Package of Workstation 15 and there disclosure package for VMware Tools 11. What is a Disclosure Package? What does it contain? And which one to actually download?
I mainly wish to enable those features at present. Somebody please guide me for this. I'll be grateful!
Hi Ilian,
Error is provided below as soon as 'Run' is clicked in VRA
Here is our observation.
In External action null check is made for the input parameter and noticed that in both the below cases, action is invoked when it is opened and also when VM is selected and set.
Input : Array/Policy
Case 1.
Visibility:No
DisplayType:Data Grid
In this case spinner is observed for the other field(policy) which is linked to external action, takes Array of Policies as input
Case 2.
Visibility:No
DisplayType:MultiValue Picker
In this case NO spinner is observed for the other field(policy) which is linked to external action, takes Array of Policies as input
Some data cannot be retrieved. If the problem persists, contact your system administrator.;
[1][policies.value][com.dell.edp.policy/getVmPolicies] 400 OK
[2][policyName.valueList][com.dell.edp.policy/getPolicyProperty] 400 OK
Thanks
Prakash
Small correction in previous reply
In External action null check is made for the input parameter and noticed that in both the below cases, action NOT is invoked when it is opened
Also analysed Container logs and couldn't find any error/exception in logs
Hello Bello carico.
I decided to run esxi 7 directly on the bare metal of my powerful PC ( I9 + RTX 2080ti ). Actually I'm using two PCs. The less powerful has an Intel I5 cpu and a GTX 1060 graphic card. The most powerful has an Intel I9 cpu with a RTX 2080 ti and its here that I loaded ESXI 7. I'm also using two monitors. I have attached one monitor to the HDMI ports of my old PC and the other one to the HDMI port of the PC where runs ESXI. I have created a new VM with Windows 10 x64 bit and I have added the pass through ability for my RTX 2080 ti as PCI device. Actually I have 3 problems :
1) the RTX 2080 ti driver is recognized only if I reinstall it from scratch when the VM restarts
2) I'm using Windows 10 inside the ESXI internal window,because I'm not able to turn on the monitor that I have attached to the HDMI port of the PC where run ESXI. Is there a way to do that ? With qemu and kvm this is possible.
3) I can't increase the resolution of windows 10 to 1920x1080
4) windows "see" only one monitor,the default microsoft adapter"
you can read the full story here :
if u want help me,I will appreciate it. thanks.
Moderator: Branched from a comment on an older thread to a new one - different errors/issues to the original thread.
Is ESXi running directly on the hardware or in a VM? If in a VM, which VMware product is running that VM?
Moderator: In future please continue your open/active thread on the same issue rather than creating a new one.
As threads cannot be merged and there are comments on both, I shall leave the 2 threads as active this time.
LuCD,
I'm using the below code. It will take time show output on the console and no report over mail. I have used the pipeline at the end of Get-VIEvent line
$fragments += $start = (Get-Date).AddDays(-1)
Get-VIEvent -Start $start -MaxSamples ([int]::MaxValue) | where{$_ -is [VMware.Vim.VmRemovedEvent]}
Sort-Object -Property CreatedTime, UserName |
ConvertTo-Html -Fragment -PreContent "<H2>VM's deleted in last 24 hours</H2>"
# Send email
$sMail = @{
From = 'abc@domain.com'
To = 'subcon@domain.com'
Subject = 'VM report'
SmtpServer = 'smtp.ab.xyz.com'
BodyAsHtml = $true
Body = ConvertTo-Html -Head $style -Body $fragments | Out-String
}
Send-MailMessage @sMail
}
Disconnect-VIServer -Server $vcenters -Confirm:$false